Ergonomic Design
Superior Functionaity
High Temperature Accuracy
Better Temperature Uniformity
Negligible Maintenance
Biological Oxygen Demand Determination
General Incubation
Serum studies
Enzyme Assays test
Microbiology Lab
CONSTRUCTION
Double walled construction, Inner chamber made of Stainless Steel 304 grade & Outer chamber made of Mild Steel powder coated. OR Inner chamber made of Stainless Steel 304 OR 316 grade & Outer chamber made of Stainless Steel 304 grade - G.M.P. model
The chamber is insulated by filling CFC Free Polyurethane
foam (PUF) or high temperature glass wool in the space
between outer body and chamber to prevent temperature
loss.
Double door - Outer metal body & Inner Acrylic Door.
Inner door - made of imported transparent Acrylic which is useful to view inner sample without opening the door and loss of temperature.
Outer door with magnetic gasket & proper handle, lock &
key.
Supplied with Adjustable Stainless Steel wire mesh shelves.
Forced Air Circulating System with Fan for Temperature Uniformity.
High Quality Compressor.
Illumination provided for inner chamber.
Control panel with indicating Lamp for Compressor, Heater and on / off switch for mains.
Inner chamber with smooth corners for easy cleaning.
Castor wheets for easy movability.
Heating Element
Heating is by specially designed air heaters.
Hermetically sealed compressor unit for CFC free cooling system as per the capacity.
Temp. Range | 5°C to 60°C | ||
Temp. Accuracy | ± 0.5°C | ||
Temp. Uniformity | ± 1°C | ||
Digital Temp. Controller | Micro-processor based Auto Tune P.I.D Digital Temperature Controller with PT 100 sensor & Resolution 0.1°C . Dual display one for process value (PV) & the another for Set Value of Tempreture (SV) | ||
Power Supply | 230 Volts A.C 50 Hz Single Phase | ||
Model | Capcity | Inner Chamber Size W x D x H | No. of Shelves |
LSC-45(a) | 3 cu.ft. (90 Ltr) | 43 x 43 x 50 cm | 2 |
LSC-45(b) | 6 cu.ft. (170 Ltr) | 51 x 51 x 70 cm | 2 |
LSC-45(c) | 10 cu.ft. (285 Ltr) | 55 x 55 x 100 cm | 3 |
LSC-45(d) | 12 cu.ft. (340 Ltr) | 60 x 60 x 100 cm | 3 |
LSC-45(e) | 16 cu.ft. (440 Ltr) | 65 x 65 x 114 cm | 4 |
Micro PLC Based Control & Recording System for Reach - In BOD Testing Chmaber with in built recording, PC interface with 21 CFR Software, Dot Matrix Printer Interface.
Data Logger for PC or Printer Aachment with soware.
4, 8, 12 Channel Data Scanner.
Door access security system.
Safety Digital Temperature Controller.
Timer
Recommended Stabilize.
© 2019 VIRT BIOTECH. All rights reserved | Design by VBT